ESD Devices.
Tanker Earthing.
Loading and unloading tank trucks and containers of flammable product is one of the most serious fire and explosion risks on a site. This system proves the ground connection before the transfer starts.

Tanker earthing that proves the ground before the transfer starts.
- Tanker Earthing
- Static Discharge
- Pump Interlock
- Zone 1 & 2, IP66
Static is the ignition
source nobody sees.
Product moving through a hose builds charge. If the tanker is not bonded to a true earth point, that charge finds its own way to ground, and a loading bay full of vapour is where it does so.
The system measures the resistance in the grounding circuit in real time and holds the interlock closed only while the bond is proven, in line with NFPA 77, API RP 2003 and CLCTR 50404.
Tanker earth monitoring
system.
| Resistance range | 10 Ohms |
|---|---|
| Input sources | True earth point and tanker body probe |
| Output type | Control relay with changeover contacts |
| Indication | GREEN LED healthy / RED LED unhealthy |
| Power supply | 230 V AC |
| Circuit protection | Internal fuses |
| Certification | CIMFR / PESO flameproof and intrinsically safe |
| Equipment marking | Ex D, Zone 1, 2 IIA IIB |
| Ingress protection | IP66 |
| Accessories | SS304 clamp and PU anti-static spiral cable |
How many loading bays?
Tell us the bay count and the products handled. We will quote the systems, the clamps and the interlock wiring.